Notifications
You must be signed in to change notification settings - Fork 72
/
Copy pathSerial.ahk
269 lines (229 loc) · 10.7 KB
/
Serial.ahk
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
; from here: http://www.autohotkey.com/forum/viewtopic.php?p=290253#290253
;########################################################################
;###### Initialize COM Subroutine #######################################
;########################################################################
Serial_Initialize(SERIAL_Settings){
;Global SERIAL_FileHandle ;uncomment this if there is a problem
;###### Build COM DCB ######
;Creates the structure that contains the COM Port number, baud rate,...
VarSetCapacity(DCB, 28)
BCD_Result := DllCall("BuildCommDCB"
,"str" , SERIAL_Settings ;lpDef
,"UInt", &DCB) ;lpDCB
If (BCD_Result <> 1){
error := DllCall("GetLastError")
MsgBox, There is a problem with Serial Port communication. `nFailed Dll BuildCommDCB, BCD_Result=%BCD_Result% `nLasterror=%error%`nThe Script Will Now Exit.
ExitApp
}
;###### Extract/Format the COM Port Number ######
StringSplit, SERIAL_Port_Temp, SERIAL_Settings, `:
SERIAL_Port_Temp1_Len := StrLen(SERIAL_Port_Temp1) ;For COM Ports > 9 \\.\ needs to prepended to the COM Port name.
If (SERIAL_Port_Temp1_Len > 4) ;So the valid names are
SERIAL_Port = \\.\%SERIAL_Port_Temp1% ; ... COM8 COM9 \\.\COM10 \\.\COM11 \\.\COM12 and so on...
Else ;
SERIAL_Port = %SERIAL_Port_Temp1%
;MsgBox, SERIAL_Port=%SERIAL_Port%
;###### Create COM File ######
;Creates the COM Port File Handle
;StringLeft, SERIAL_Port, SERIAL_Settings, 4 ; 7/23/08 This line is replaced by the "Extract/Format the COM Port Number" section above.
SERIAL_FileHandle := DllCall("CreateFile"
,"Str" , SERIAL_Port ;File Name
,"UInt", 0xC0000000 ;Desired Access
,"UInt", 3 ;Safe Mode
,"UInt", 0 ;Security Attributes
,"UInt", 3 ;Creation Disposition
,"UInt", 0 ;Flags And Attributes
,"UInt", 0 ;Template File
,"Cdecl Int")
If (SERIAL_FileHandle < 1){
error := DllCall("GetLastError")
MsgBox, There is a problem with Serial Port communication. `nFailed Dll CreateFile, SERIAL_FileHandle=%SERIAL_FileHandle% `nLasterror=%error%`nThe Script Will Now Exit.
ExitApp
}
;###### Set COM State ######
;Sets the COM Port number, baud rate,...
SCS_Result := DllCall("SetCommState"
,"UInt", SERIAL_FileHandle ;File Handle
,"UInt", &DCB) ;Pointer to DCB structure
If (SCS_Result <> 1){
error := DllCall("GetLastError")
MsgBox, There is a problem with Serial Port communication. `nFailed Dll SetCommState, SCS_Result=%SCS_Result% `nLasterror=%error%`nThe Script Will Now Exit.
Serial_Close(SERIAL_FileHandle)
ExitApp
}
;###### Create the SetCommTimeouts Structure ######
ReadIntervalTimeout = 0xffffffff
ReadTotalTimeoutMultiplier = 0x00000000
ReadTotalTimeoutConstant = 0x00000000
WriteTotalTimeoutMultiplier= 0x00000000
WriteTotalTimeoutConstant = 0x00000000
VarSetCapacity(Data, 20, 0) ; 5 * sizeof(DWORD)
NumPut(ReadIntervalTimeout, Data, 0, "UInt")
NumPut(ReadTotalTimeoutMultiplier, Data, 4, "UInt")
NumPut(ReadTotalTimeoutConstant, Data, 8, "UInt")
NumPut(WriteTotalTimeoutMultiplier, Data, 12, "UInt")
NumPut(WriteTotalTimeoutConstant, Data, 16, "UInt")
;###### Set the COM Timeouts ######
SCT_result := DllCall("SetCommTimeouts"
,"UInt", SERIAL_FileHandle ;File Handle
,"UInt", &Data) ;Pointer to the data structure
If (SCT_result <> 1){
error := DllCall("GetLastError")
MsgBox, There is a problem with Serial Port communication. `nFailed Dll SetCommState, SCT_result=%SCT_result% `nLasterror=%error%`nThe Script Will Now Exit.
Serial_Close(SERIAL_FileHandle)
ExitApp
}
Return SERIAL_FileHandle
}
;########################################################################
;###### Close COM Subroutine ############################################
;########################################################################
Serial_Close(SERIAL_FileHandle){
;###### Close the COM File ######
CH_result := DllCall("CloseHandle", "UInt", SERIAL_FileHandle)
If (CH_result <> 1)
MsgBox, Failed Dll CloseHandle CH_result=%CH_result%
Return
}
;########################################################################
;###### Write to COM Subroutines ########################################
;########################################################################
Serial_Write(SERIAL_FileHandle, Message){
;Global SERIAL_FileHandle
SetFormat, Integer, DEC
;Parse the Message. Byte0 is the number of bytes in the array.
StringSplit, Byte, Message, `,
Data_Length := Byte0
;msgbox, Data_Length=%Data_Length% b1=%Byte1% b2=%Byte2% b3=%Byte3% b4=%Byte4%
;Set the Data buffer size, prefill with 0xFF.
VarSetCapacity(Data, Byte0, 0xFF)
;Write the Message into the Data buffer
i=1
Loop %Byte0% {
NumPut(Byte%i%, Data, (i-1) , "UChar")
;msgbox, %i%
i++
}
;msgbox, Data string=%Data%
;###### Write the data to the COM Port ######
WF_Result := DllCall("WriteFile"
,"UInt" , SERIAL_FileHandle ;File Handle
,"UInt" , &Data ;Pointer to string to send
,"UInt" , Data_Length ;Data Length
,"UInt*", Bytes_Sent ;Returns pointer to num bytes sent
,"Int" , "NULL")
If (WF_Result <> 1 or Bytes_Sent <> Data_Length)
MsgBox, Failed Dll WriteFile to COM Port, result=%WF_Result% `nData Length=%Data_Length% `nBytes_Sent=%Bytes_Sent%
Return Bytes_Sent
}
;########################################################################
;###### Read from COM Subroutines #######################################
;########################################################################
Serial_Read(SERIAL_FileHandle, Num_Bytes, byref Bytes_Received = ""){
;Global SERIAL_FileHandle
;Global SERIAL_Port
;Global Bytes_Received
SetFormat, Integer, HEX
;Set the Data buffer size, prefill with 0x55 = ASCII character "U"
;VarSetCapacity won't assign anything less than 3 bytes. Meaning: If you
; tell it you want 1 or 2 byte size variable it will give you 3.
Data_Length := VarSetCapacity(Data, Num_Bytes, 0)
;msgbox, Data_Length=%Data_Length%
;Bytes_Received := 0
;###### Read the data from the COM Port ######
;msgbox, SERIAL_FileHandle=%SERIAL_FileHandle% `nNum_Bytes=%Num_Bytes%
Read_Result := DllCall("ReadFile"
,"UInt" , SERIAL_FileHandle ; hFile
,"Str" , Data ; lpBuffer
,"Int" , Num_Bytes ; nNumberOfBytesToRead
,"UInt*", Bytes_Received ; lpNumberOfBytesReceived
,"Int" , 0) ; lpOverlapped
;MsgBox, Read_Result=%Read_Result% `nBR=%Bytes_Received% ,`nData=%Data%
If (Read_Result <> 1){
MsgBox, There is a problem with Serial Port communication. `nFailed Dll ReadFile on COM Port, result=%Read_Result% - The Script Will Now Exit.
Serial_Close(SERIAL_FileHandle)
Exit
}
;###### Format the received data ######
;This loop is necessary because AHK doesn't handle NULL (0x00) characters very nicely.
;Quote from AHK documentation under DllCall:
; "Any binary zero stored in a variable by a function will hide all data to the right
; of the zero; that is, such data cannot be accessed or changed by most commands and
; functions. However, such data can be manipulated by the address and dereference operators
; (& and *), as well as DllCall itself."
i = 0
Data_HEX =
Loop %Bytes_Received% {
;First byte into the Rx FIFO ends up at position 0
Data_HEX_Temp := NumGet(Data, i, "UChar") ;Convert to HEX byte-by-byte
StringTrimLeft, Data_HEX_Temp, Data_HEX_Temp, 2 ;Remove the 0x (added by the above line) from the front
;If there is only 1 character then add the leading "0'
Length := StrLen(Data_HEX_Temp)
If (Length =1)
Data_HEX_Temp = 0%Data_HEX_Temp%
i++
;Put it all together
Data_HEX .= Data_HEX_Temp
}
;MsgBox, Read_Result=%Read_Result% `nBR=%Bytes_Received% ,`nData_HEX=%Data_HEX%
SetFormat, Integer, DEC
Data := Data_HEX
Return Data
}
;########################################################################
;###### Read from COM Subroutines #######################################
;########################################################################
Serial_Read_Raw(SERIAL_FileHandle, Num_Bytes, mode = "",byref Bytes_Received = ""){
;Global SERIAL_FileHandle
;Global SERIAL_Port
;Global Bytes_Received
SetFormat, Integer, HEX
;Set the Data buffer size, prefill with 0x55 = ASCII character "U"
;VarSetCapacity won't assign anything less than 3 bytes. Meaning: If you
; tell it you want 1 or 2 byte size variable it will give you 3.
Data_Length := VarSetCapacity(Data, Num_Bytes, 0)
;msgbox, Data_Length=%Data_Length%
;###### Read the data from the COM Port ######
;msgbox, SERIAL_FileHandle=%SERIAL_FileHandle% `nNum_Bytes=%Num_Bytes%
Read_Result := DllCall("ReadFile"
,"UInt" , SERIAL_FileHandle ; hFile
,"Str" , Data ; lpBuffer
,"Int" , Num_Bytes ; nNumberOfBytesToRead
,"UInt*", Bytes_Received ; lpNumberOfBytesReceived
,"Int" , 0) ; lpOverlapped
;MsgBox, Read_Result=%Read_Result% `nBR=%Bytes_Received% ,`nData=%Data%
If (Read_Result <> 1){
MsgBox, There is a problem with Serial Port communication. `nFailed Dll ReadFile on COM Port, result=%Read_Result% - The Script Will Now Exit.
Serial_Close(SERIAL_FileHandle)
Exit
}
;if you know the data coming back will not contain any binary zeros (0x00), you can request the 'raw' response
If (mode = "raw")
Return Data
;###### Format the received data ######
;This loop is necessary because AHK doesn't handle NULL (0x00) characters very nicely.
;Quote from AHK documentation under DllCall:
; "Any binary zero stored in a variable by a function will hide all data to the right
; of the zero; that is, such data cannot be accessed or changed by most commands and
; functions. However, such data can be manipulated by the address and dereference operators
; (& and *), as well as DllCall itself."
i = 0
Data_HEX =
Loop %Bytes_Received%
{
;First byte into the Rx FIFO ends up at position 0
Data_HEX_Temp := NumGet(Data, i, "UChar") ;Convert to HEX byte-by-byte
StringTrimLeft, Data_HEX_Temp, Data_HEX_Temp, 2 ;Remove the 0x (added by the above line) from the front
;If there is only 1 character then add the leading "0'
Length := StrLen(Data_HEX_Temp)
If (Length =1)
Data_HEX_Temp = 0%Data_HEX_Temp%
i++
;Put it all together
Data_HEX .= Data_HEX_Temp
}
;MsgBox, Read_Result=%Read_Result% `nBR=%Bytes_Received% ,`nData_HEX=%Data_HEX%
SetFormat, Integer, DEC
Data := Data_HEX