forked from JoshLipps/mibbrowser-node
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathRFC1231-MIB
869 lines (782 loc) · 39.4 KB
/
RFC1231-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
-- Changes for RFC1231 (Token Ring MIB):
-- Changes from RFC-1239 applied which include:
-- removing import of experimental,
-- adding import of transmission, changing
-- dot5 to be { transmission 9 }
-- instead of { experimental 4 }
-- Added import for Counter.
-- Changed the status from optional to mandatory for
-- dot5StatsFreqErrors.
RFC1231-MIB DEFINITIONS ::= BEGIN
-- RFC1231
-- May 91
-- IEEE 802.5 Token Ring MIB
IMPORTS
Counter
FROM RFC1155-SMI
transmission
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
dot5 OBJECT IDENTIFIER ::= { transmission 9 }
-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet
-- address in the
-- "canonical" order
-- defined by IEEE 802.1a, i.e., as if it were transmitted
-- least significant bit first, even though 802.5 (in
-- contrast to other 802.x protocols) requires MAC addresses
-- to be transmitted most significant bit first.
--
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.
-- The Interface Table
-- This table contains state and parameter information which
-- is specific to 802.5 interfaces. It is mandatory that
-- systems having 802.5 interfaces implement this table in
-- addition to the generic interfaces table [4,6] and its
-- generic extensions [11].
dot5Table OBJECT-TYPE
SYNTAX SEQUENCE OF Dot5Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Ring interface
parameters and state variables, one entry
per 802.5 interface."
::= { dot5 1 }
dot5Entry OBJECT-TYPE
SYNTAX Dot5Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Ring status and parameter
values for an 802.5 interface."
INDEX { dot5IfIndex }
::= { dot5Table 1 }
Dot5Entry
::= SEQUENCE {
dot5IfIndex
INTEGER,
dot5Commands
INTEGER,
dot5RingStatus
INTEGER,
dot5RingState
INTEGER,
dot5RingOpenStatus
INTEGER,
dot5RingSpeed
INTEGER,
dot5UpStream
MacAddress,
dot5ActMonParticipate
INTEGER,
dot5Functional
MacAddress
}
dot5IfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { dot5Entry 1 }
dot5Commands OBJECT-TYPE
SYNTAX INTEGER {
no-op(1),
open(2),
reset(3),
close(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is set to the value of
open(2), the station should go into the
open state. The progress and success of
the open is given by the values of the
objects dot5RingState and
dot5RingOpenStatus.
When this object is set to the value
of reset(3), then the station should do
a reset. On a reset, all MIB counters
should retain their values, if possible.
Other side affects are dependent on the
hardware chip set.
When this object is set to the value
of close(4), the station should go into
the stopped state by removing itself
from the ring.
Setting this object to a value of
no-op(1) has no effect.
When read, this object always has a
value of no-op(1)."
::= { dot5Entry 2 }
dot5RingStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current interface status which can
be used to diagnose fluctuating problems
that can occur on token rings, after a
station has successfully been added to
the ring.
Before an open is completed, this
object has the value for the 'no status'
condition. The dot5RingState and
dot5RingOpenStatus objects provide for
debugging problems when the station
can not even enter the ring.
The object's value is a sum of
values, one for each currently applicable
condition. The following values are
defined for various conditions:
0 = No Problems detected
32 = Ring Recovery
64 = Single Station
256 = Remove Received
512 = reserved
1024 = Auto-Removal Error
2048 = Lobe Wire Fault
4096 = Transmit Beacon
8192 = Soft Error
16384 = Hard Error
32768 = Signal Loss
131072 = no status, open not completed."
::= { dot5Entry 3 }
dot5RingState OBJECT-TYPE
SYNTAX INTEGER {
opened(1),
closed(2),
opening(3),
closing(4),
openFailure(5),
ringFailure(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current interface state with respect
to entering or leaving the ring."
::= { dot5Entry 4 }
dot5RingOpenStatus OBJECT-TYPE
SYNTAX INTEGER {
noOpen(1), -- no open attempted
badParam(2),
lobeFailed(3),
signalLoss(4),
insertionTimeout(5),
ringFailed(6),
beaconing(7),
duplicateMAC(8),
requestFailed(9),
removeReceived(10),
open(11) -- last open successful
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the success, or the
reason for failure, of the station's most
recent attempt to enter the ring."
::= { dot5Entry 5 }
dot5RingSpeed OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
oneMegabit(2),
fourMegabit(3),
sixteenMegabit(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ring's bandwidth."
::= { dot5Entry 6 }
dot5UpStream OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC-address of the up stream neighbor
station in the ring."
::= { dot5Entry 7 }
dot5ActMonParticipate OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object has a value of true(1) then
this interface will participate in the
active monitor selection process. If the
value is false(2) then it will not.
Setting this object might not have an
effect until the next time the interface
is opened."
::= { dot5Entry 8 }
dot5Functional OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The bit mask of all Token Ring functional
addresses for which this interface will
accept frames."
::= { dot5Entry 9 }
-- The Statistics Table
-- This table contains statistics and error counter which are
-- specific to 802.5 interfaces. It is mandatory that systems
-- having 802.5 interfaces implement this table.
dot5StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot5StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing Token Ring statistics,
one entry per 802.5 interface.
All the statistics are defined using
the syntax Counter as 32-bit wrap around
counters. Thus, if an interface's
hardware maintains these statistics in
16-bit counters, then the agent must read
the hardware's counters frequently enough
to prevent loss of significance, in order
to maintain 32-bit counters in software."
::= { dot5 2 }
dot5StatsEntry OBJECT-TYPE
SYNTAX Dot5StatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry contains the 802.5 statistics
for a particular interface."
INDEX { dot5StatsIfIndex }
::= { dot5StatsTable 1 }
Dot5StatsEntry
::= SEQUENCE {
dot5StatsIfIndex
INTEGER,
dot5StatsLineErrors
Counter,
dot5StatsBurstErrors
Counter,
dot5StatsACErrors
Counter,
dot5StatsAbortTransErrors
Counter,
dot5StatsInternalErrors
Counter,
dot5StatsLostFrameErrors
Counter,
dot5StatsReceiveCongestions
Counter,
dot5StatsFrameCopiedErrors
Counter,
dot5StatsTokenErrors
Counter,
dot5StatsSoftErrors
Counter,
dot5StatsHardErrors
Counter,
dot5StatsSignalLoss
Counter,
dot5StatsTransmitBeacons
Counter,
dot5StatsRecoverys
Counter,
dot5StatsLobeWires
Counter,
dot5StatsRemoves
Counter,
dot5StatsSingles
Counter,
dot5StatsFreqErrors
Counter
}
dot5StatsIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6], for
the same interface."
::= { dot5StatsEntry 1 }
dot5StatsLineErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a frame
or token is copied or repeated by a
station, the E bit is zero in the frame
or token and one of the following
conditions exists: 1) there is a
non-data bit (J or K bit) between the SD
and the ED of the frame or token, or
2) there is an FCS error in the frame."
::= { dot5StatsEntry 2 }
dot5StatsBurstErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
detects the absence of transitions for five
half-bit timers (burst-five error)."
::= { dot5StatsEntry 3 }
dot5StatsACErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
receives an AMP or SMP frame in which A is
equal to C is equal to 0, and then receives
another SMP frame with A is equal to C is
equal to 0 without first receiving an AMP
frame. It denotes a station that cannot set
the AC bits properly."
::= { dot5StatsEntry 4 }
dot5StatsAbortTransErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
transmits an abort delimiter while
transmitting."
::= { dot5StatsEntry 5 }
dot5StatsInternalErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
recognizes an internal error."
::= { dot5StatsEntry 6 }
dot5StatsLostFrameErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
is transmitting and its TRR timer expires.
This condition denotes a condition where a
transmitting station in strip mode does not
receive the trailer of the frame before the
TRR timer goes off."
::= { dot5StatsEntry 7 }
dot5StatsReceiveCongestions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
recognizes a frame addressed to its
specific address, but has no available
buffer space indicating that the station
is congested."
::= { dot5StatsEntry 8 }
dot5StatsFrameCopiedErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
recognizes a frame addressed to its
specific address and detects that the FS
field A bits are set to 1 indicating a
possible line hit or duplicate address."
::= { dot5StatsEntry 9 }
dot5StatsTokenErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented when a station
acting as the active monitor recognizes an
error condition that needs a token
transmitted."
::= { dot5StatsEntry 10 }
dot5StatsSoftErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Soft Errors the interface
has detected. It directly corresponds to
the number of Report Error MAC frames
that this interface has transmitted.
Soft Errors are those which are
recoverable by the MAC layer protocols."
::= { dot5StatsEntry 11 }
dot5StatsHardErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this interface has
detected an immediately recoverable
fatal error. It denotes the number of
times this interface is either
transmitting or receiving beacon MAC
frames."
::= { dot5StatsEntry 12 }
dot5StatsSignalLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this interface has
detected the loss of signal condition from
the ring."
::= { dot5StatsEntry 13 }
dot5StatsTransmitBeacons OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this interface has
transmitted a beacon frame."
::= { dot5StatsEntry 14 }
dot5StatsRecoverys OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Claim Token MAC frames
received or transmitted after the interface
has received a Ring Purge MAC frame. This
counter signifies the number of times the
ring has been purged and is being recovered
back into a normal operating state."
::= { dot5StatsEntry 15 }
dot5StatsLobeWires OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the interface has
detected an open or short circuit in the
lobe data path. The adapter will be closed
and dot5RingState will signify this
condition."
::= { dot5StatsEntry 16 }
dot5StatsRemoves OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the interface has
received a Remove Ring Station MAC frame
request. When this frame is received
the interface will enter the close state
and dot5RingState will signify this
condition."
::= { dot5StatsEntry 17 }
dot5StatsSingles OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the interface has
sensed that it is the only station on the
ring. This will happen if the interface
is the first one up on a ring, or if
there is a hardware problem."
::= { dot5StatsEntry 18 }
dot5StatsFreqErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the interface has
detected that the frequency of the
incoming signal differs from the expected
frequency by more than that specified by
the IEEE 802.5 standard, see chapter 7
in [10]."
::= { dot5StatsEntry 19 }
-- The Timer Table
-- This group contains the values of the timers defined in
-- [10] for 802.5 interfaces. It is optional that systems
-- having 802.5 interfaces implement this group.
dot5TimerTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot5TimerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains Token Ring interface
timer values, one entry per 802.5
interface."
::= { dot5 5 }
dot5TimerEntry OBJECT-TYPE
SYNTAX Dot5TimerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Token Ring timer values for an
802.5 interface."
INDEX { dot5TimerIfIndex }
::= { dot5TimerTable 1 }
Dot5TimerEntry
::= SEQUENCE {
dot5TimerIfIndex
INTEGER,
dot5TimerReturnRepeat
INTEGER,
dot5TimerHolding
INTEGER,
dot5TimerQueuePDU
INTEGER,
dot5TimerValidTransmit
INTEGER,
dot5TimerNoToken
INTEGER,
dot5TimerActiveMon
INTEGER,
dot5TimerStandbyMon
INTEGER,
dot5TimerErrorReport
INTEGER,
dot5TimerBeaconTransmit
INTEGER,
dot5TimerBeaconReceive
INTEGER
}
dot5TimerIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains timer values. The value of
this object for a particular interface
has the same value as the ifIndex
object, defined in [4,6], for the same
interface."
::= { dot5TimerEntry 1 }
dot5TimerReturnRepeat OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value used to ensure the
interface will return to Repeat State, in
units of 100 micro-seconds. The value
should be greater than the maximum ring
latency.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 2 }
dot5TimerHolding OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum period of time a station is
permitted to transmit frames after capturing
a token, in units of 100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 3 }
dot5TimerQueuePDU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value for enqueuing of an SMP
PDU after reception of an AMP or SMP
frame in which the A and C bits were
equal to 0, in units of 100
micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 4 }
dot5TimerValidTransmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value used by the active
monitor to detect the absence of valid
transmissions, in units of 100
micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 5 }
dot5TimerNoToken OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value used to recover from
various-related error situations [9].
If N is the maximum number of stations on
the ring, the value of this timer is
normally:
dot5TimerReturnRepeat + N*dot5TimerHolding.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 6 }
dot5TimerActiveMon OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value used by the active
monitor to stimulate the enqueuing of an
AMP PDU for transmission, in units of
100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 7 }
dot5TimerStandbyMon OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value used by the stand-by
monitors to ensure that there is an active
monitor on the ring and to detect a
continuous stream of tokens, in units of
100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 8 }
dot5TimerErrorReport OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value which determines how
often a station shall send a Report Error
MAC frame to report its error counters,
in units of 100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 9 }
dot5TimerBeaconTransmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value which determines how
long a station shall remain in the state
of transmitting Beacon frames before
entering the Bypass state, in units of
100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 10 }
dot5TimerBeaconReceive OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time-out value which determines how
long a station shall receive Beacon
frames from its downstream neighbor
before entering the Bypass state, in
units of 100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers."
::= { dot5TimerEntry 11 }
-- 802.5 Interface Tests
dot5Tests OBJECT IDENTIFIER ::= { dot5 3 }
-- The extensions to the interfaces table proposed in [11]
-- define a table object, ifExtnsTestTable, through which a
-- network manager can instruct an agent to test an interface
-- for various faults. A test to be performed is identified
-- (as the value of ifExtnsTestType) via an OBJECT IDENTIFIER.
--
-- The Full-Duplex Loop Back Test is a common test, defined
-- in [11] as:
--
-- testFullDuplexLoopBack
--
-- Invoking this test on a 802.5 interface causes the
-- interface to check the path from memory through the
-- chip set's internal logic and back to memory, thus
-- checking the proper functioning of the systems's
-- interface to the chip set.
-- The Insert Function test is defined by:
testInsertFunc OBJECT IDENTIFIER ::= { dot5Tests 1 }
-- Invoking this test causes the station to test the insert
-- ring logic of the hardware if the station's lobe media
-- cable is connected to a wiring concentrator. Note that
-- this command inserts the station into the network, and
-- thus, could cause problems if the station is connected
-- to a operational network.
-- 802.5 Hardware Chip Sets
dot5ChipSets OBJECT IDENTIFIER ::= { dot5 4 }
-- The extensions to the interfaces table proposed in [11]
-- define an object, ifExtnsChipSet, with the syntax of
-- OBJECT IDENTIFIER, to identify the hardware chip set in
-- use by an interface. That definition specifies just
-- one applicable object identifier:
--
-- unknownChipSet
--
-- for use as the value of ifExtnsChipSet when the specific
-- chip set is unknown.
--
-- This MIB defines the following for use as values of
-- ifExtnsChipSet:
-- IBM 16/4 Mb/s
chipSetIBM16 OBJECT IDENTIFIER ::= { dot5ChipSets 1 }
-- TI 4Mb/s
chipSetTItms380 OBJECT IDENTIFIER ::= { dot5ChipSets 2 }
-- TI 16/4 Mb/s
chipSetTItms380c16 OBJECT IDENTIFIER ::= { dot5ChipSets 3 }
END