forked from JoshLipps/mibbrowser-node
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathRFC1271-MIB
3356 lines (2988 loc) · 144 KB
/
RFC1271-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
RFC1271-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter FROM RFC1155-SMI
mib-2, DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212;
-- This MIB module uses the extended OBJECT-TYPE macro as
-- defined in [9].
-- Remote Network Monitoring MIB
rmon OBJECT IDENTIFIER ::= { mib-2 16 }
-- textual conventions
OwnerString ::= DisplayString
-- This data type is used to model an administratively
-- assigned name of the owner of a resource. This
-- information is taken from the NVT ASCII character set.
-- It is suggested that this name contain one or more
-- of the following:
-- IP address, management station name, network manager's
-- name, location, or phone number.
-- In some cases the agent itself will be the owner of
-- an entry. In these cases, this string shall be set
-- to a string starting with 'monitor'.
--
-- SNMP access control is articulated entirely in terms of
-- the contents of MIB views; access to a particular SNMP
-- object instance depends only upon its presence or
-- absence in a particular MIB view and never upon its
-- value or the value of related object instances. Thus,
-- objects of this type afford resolution of resource
-- contention only among cooperating managers; they
-- realize no access control function with respect
-- to uncooperative parties.
--
-- By convention, objects with this syntax are declared
-- as having
--
-- SIZE (0..127)
EntryStatus ::= INTEGER
{ valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
-- The status of a table entry.
--
-- Setting this object to the value invalid(4) has the
-- effect of invalidating the corresponding entry.
-- That is, it effectively disassociates the mapping
-- identified with said entry.
-- It is an implementation-specific matter as to whether
-- the agent removes an invalidated entry from the table.
-- Accordingly, management stations must be prepared to
-- receive tabular information from agents that corresponds
-- to entries currently not in use. Proper
-- interpretation of such entries requires examination
-- of the relevant EntryStatus object.
--
-- An existing instance of this object cannot be set to
-- createRequest(2). This object may only be set to
-- createRequest(2) when this instance is created. When
-- this object is created, the agent may wish to create
-- supplemental object instances to complete a conceptual
-- row in this table. Immediately after completing the
-- create operation, the agent must set this object to
-- underCreation(3).
--
-- Entries shall exist in the underCreation(3) state until
-- the management station is finished configuring the
-- entry and sets this object to valid(1) or aborts,
-- setting this object to invalid(4). If the agent
-- determines that an entry has been in the
-- underCreation(3) state for an abnormally long time,
-- it may decide that the management station has
-- crashed. If the agent makes this decision,
-- it may set this object to invalid(4) to reclaim the
-- entry. A prudent agent will understand that the
-- management station may need to wait for human input
-- and will allow for that possibility in its
-- determination of this abnormally long period.
statistics OBJECT IDENTIFIER ::= { rmon 1 }
history OBJECT IDENTIFIER ::= { rmon 2 }
alarm OBJECT IDENTIFIER ::= { rmon 3 }
hosts OBJECT IDENTIFIER ::= { rmon 4 }
hostTopN OBJECT IDENTIFIER ::= { rmon 5 }
matrix OBJECT IDENTIFIER ::= { rmon 6 }
filter OBJECT IDENTIFIER ::= { rmon 7 }
capture OBJECT IDENTIFIER ::= { rmon 8 }
event OBJECT IDENTIFIER ::= { rmon 9 }
-- The Statistics Group
--
-- Implementation of the Statistics group is optional.
--
-- The statistics group contains statistics measured by the
-- probe for each monitored interface on this device. These
-- statistics take the form of free running counters that
-- start from zero when a valid entry is created.
--
-- This group currently has statistics defined only for
-- Ethernet interfaces. Each etherStatsEntry contains
-- statistics for one Ethernet interface. The probe must
-- create one etherStats entry for each monitored Ethernet
-- interface on the device.
etherStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Ethernet statistics entries."
::= { statistics 1 }
etherStatsEntry OBJECT-TYPE
SYNTAX EtherStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A collection of statistics kept for a particular
Ethernet interface."
INDEX { etherStatsIndex }
::= { etherStatsTable 1 }
EtherStatsEntry ::= SEQUENCE {
etherStatsIndex INTEGER (1..65535),
etherStatsDataSource OBJECT IDENTIFIER,
etherStatsDropEvents Counter,
etherStatsOctets Counter,
etherStatsPkts Counter,
etherStatsBroadcastPkts Counter,
etherStatsMulticastPkts Counter,
etherStatsCRCAlignErrors Counter,
etherStatsUndersizePkts Counter,
etherStatsOversizePkts Counter,
etherStatsFragments Counter,
etherStatsJabbers Counter,
etherStatsCollisions Counter,
etherStatsPkts64Octets Counter,
etherStatsPkts65to127Octets Counter,
etherStatsPkts128to255Octets Counter,
etherStatsPkts256to511Octets Counter,
etherStatsPkts512to1023Octets Counter,
etherStatsPkts1024to1518Octets Counter,
etherStatsOwner OwnerString,
etherStatsStatus INTEGER
}
etherStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object uniquely identifies this
etherStats entry."
::= { etherStatsEntry 1 }
etherStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the source of the data that
this etherStats entry is configured to analyze. This
source can be any ethernet interface on this device.
In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in [4,6], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
This object may not be modified if the associated
etherStatsStatus object is equal to valid(1)."
::= { etherStatsEntry 2 }
etherStatsDropEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources.
Note that this number is not necessarily the number of
packets dropped; it is just the number of times this
condition has been detected."
::= { etherStatsEntry 3 }
etherStatsOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets)."
::= { etherStatsEntry 4 }
etherStatsPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error packets)
received."
::= { etherStatsEntry 5 }
etherStatsBroadcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of good packets received that were
directed to the broadcast address."
::= { etherStatsEntry 6 }
etherStatsMulticastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of good packets received that were
directed to a multicast address. Note that this
number does not include packets directed to the
broadcast address."
::= { etherStatsEntry 7 }
etherStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but were not an integral number
of octets in length or had a bad Frame Check
Sequence (FCS)."
::= { etherStatsEntry 8 }
etherStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { etherStatsEntry 9 }
etherStatsOversizePkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { etherStatsEntry 10 }
etherStatsFragments OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received that were not an
integral number of octets in length or that had a bad
Frame Check Sequence (FCS), and were less than 64
octets in length (excluding framing bits but
including FCS octets)."
::= { etherStatsEntry 11 }
etherStatsJabbers OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and were not an
integral number of octets in length or had
a bad Frame Check Sequence (FCS)."
::= { etherStatsEntry 12 }
etherStatsCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment."
::= { etherStatsEntry 13 }
etherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 14 }
etherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 15 }
etherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 16 }
etherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 17 }
etherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 18 }
etherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets (including error
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 19 }
etherStatsOwner OBJECT-TYPE
SYNTAX OwnerString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { etherStatsEntry 20 }
etherStatsStatus OBJECT-TYPE
SYNTAX EntryStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of this etherStats entry."
::= { etherStatsEntry 21 }
-- The History Group
-- Implementation of the History group is optional.
--
-- The history group records periodic statistical samples from
-- a network and stores them for later retrieval. The
-- historyControl table stores configuration entries that each
-- define an interface, polling period, and other parameters.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table. Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken. Currently the only media-
-- specific table defined is the etherHistoryTable, for
-- Ethernet networks.
--
-- If the probe keeps track of the time of day, it should
-- start the first sample of the history at a time such that
-- when the next hour of the day begins, a sample is
-- started at that instant. This tends to make more
-- user-friendly reports, and enables comparison of reports
-- from different probes that have relatively accurate time
-- of day.
--
-- The monitor is encouraged to add two history control entries
-- per monitored interface upon initialization that describe
-- a short term and a long term polling period. Suggested
-- parameters are 30 seconds for the short term polling
-- period and 30 minutes for the long term period.
historyControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HistoryControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of history control entries."
::= { history 1 }
historyControlEntry OBJECT-TYPE
SYNTAX HistoryControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of parameters that set up a periodic
sampling of statistics."
INDEX { historyControlIndex }
::= { historyControlTable 1 }
HistoryControlEntry ::= SEQUENCE {
historyControlIndex INTEGER (1..65535),
historyControlDataSource OBJECT IDENTIFIER,
historyControlBucketsRequested INTEGER (1..65535),
historyControlBucketsGranted INTEGER (1..65535),
historyControlInterval INTEGER (1..3600),
historyControlOwner OwnerString,
historyControlStatus INTEGER
}
historyControlIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies an entry in the
historyControl table. Each such entry defines a
set of samples at a particular interval for an
interface on the device."
::= { historyControlEntry 1 }
historyControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on behalf of this
historyControlEntry. This source can be any
interface on this device. In order to identify
a particular interface, this object shall identify
the instance of the ifIndex object, defined
in [4,6], for the desired interface. For example,
if an entry were to receive data from interface #1,
this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
::= { historyControlEntry 2 }
historyControlBucketsRequested OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated with this
historyControl entry.
When this object is created or modified, the probe
should set historyControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { historyControlEntry 3 }
historyControlBucketsGranted OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of discrete sampling intervals
over which data shall be saved in the part of
the media-specific table associated with this
historyControl entry.
When the associated historyControlBucketsRequested
object is created or modified, the probe
should set this object as closely to the requested
value as is possible for the particular
probe implementation and available resources. The
probe must not lower this value except as a result
of a modification to the associated
historyControlBucketsRequested object.
There will be times when the actual number of
buckets associated with this entry is less than
the value of this object. In this case, at the
end of each sampling interval, a new bucket will
be added to the media-specific table.
When the number of buckets reaches the value of
this object and a new bucket is to be added to the
media-specific table, the oldest bucket associated
with this historyControlEntry shall be deleted by
the agent so that the new bucket can be added.
When the value of this object changes to a value less
than the current value, entries are deleted
from the media-specific table associated with this
historyControlEntry. Enough of the oldest of these
entries shall be deleted by the agent so that their
number remains less than or equal to the new value of
this object.
When the value of this object changes to a value
greater than the current value, the number of
associated media-specific entries may be allowed
to grow."
::= { historyControlEntry 4 }
historyControlInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControl entry. This interval can
be set to any number of seconds between 1 and
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could overflow
in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
::= { historyControlEntry 5 }
historyControlOwner OBJECT-TYPE
SYNTAX OwnerString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { historyControlEntry 6 }
historyControlStatus OBJECT-TYPE
SYNTAX EntryStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of this historyControl entry.
Each instance of the media-specific table associated
with this historyControlEntry will be deleted by the
agent if this historyControlEntry is not equal to
valid(1)."
::= { historyControlEntry 7 }
-- Ether History table
etherHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Ethernet history entries."
::= { history 2 }
etherHistoryEntry OBJECT-TYPE
SYNTAX EtherHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An historical sample of Ethernet statistics on a
particular Ethernet interface. This sample is
associated with the historyControlEntry which set
up the parameters for a regular collection of these
samples."
INDEX { etherHistoryIndex , etherHistorySampleIndex }
::= { etherHistoryTable 1 }
EtherHistoryEntry ::= SEQUENCE {
etherHistoryIndex INTEGER (1..65535),
etherHistorySampleIndex INTEGER,
etherHistoryIntervalStart TimeTicks,
etherHistoryDropEvents Counter,
etherHistoryOctets Counter,
etherHistoryPkts Counter,
etherHistoryBroadcastPkts Counter,
etherHistoryMulticastPkts Counter,
etherHistoryCRCAlignErrors Counter,
etherHistoryUndersizePkts Counter,
etherHistoryOversizePkts Counter,
etherHistoryFragments Counter,
etherHistoryJabbers Counter,
etherHistoryCollisions Counter,
etherHistoryUtilization INTEGER (0..10000)
}
etherHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The history of which this entry is a part. The
history identified by a particular value of this
index is the same history as identified
by the same value of historyControlIndex."
::= { etherHistoryEntry 1 }
etherHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies the particular
sample this entry represents among all samples
associated with the same historyControlEntry.
This index starts at 1 and increases by one
as each new sample is taken."
::= { etherHistoryEntry 2 }
etherHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the start of the interval
over which this sample was measured. If the probe
keeps track of the time of day, it should start
the first sample of the history at a time such that
when the next hour of the day begins, a sample is
started at that instant. Note that following this
rule may require the probe to delay collecting the
first sample of the history, as each sample must be
of the same interval. Also note that the sample which
is currently being collected is not accessible in this
table until the end of its interval."
::= { etherHistoryEntry 3 }
etherHistoryDropEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources
during this interval. Note that this number is not
necessarily the number of packets dropped, it is just
the number of times this condition has been detected."
::= { etherHistoryEntry 4 }
etherHistoryOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets)."
::= { etherHistoryEntry 5 }
etherHistoryPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets (including error packets)
received during this sampling interval."
::= { etherHistoryEntry 6 }
etherHistoryBroadcastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets received during this
sampling interval that were directed to the
broadcast address."
::= { etherHistoryEntry 7 }
etherHistoryMulticastPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets received during this
sampling interval that were directed to a
multicast address. Note that this number does not
include packets addressed to the broadcast address."
::= { etherHistoryEntry 8 }
etherHistoryCRCAlignErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received during this
sampling interval that had a length (excluding
framing bits but including FCS octets) between
64 and 1518 octets, inclusive, but were not an
integral number of octets in length or had a
bad Frame Check Sequence (FCS)."
::= { etherHistoryEntry 9 }
etherHistoryUndersizePkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received during this
interval that were less than 64 octets long
(excluding framing bits but including FCS
octets) and were otherwise well formed."
::= { etherHistoryEntry 10 }
etherHistoryOversizePkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received during this
interval that were longer than 1518 octets
(excluding framing bits but including FCS
octets) but were otherwise well formed."
::= { etherHistoryEntry 11 }
etherHistoryFragments OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received during this
sampling interval that were not an integral
number of octets in length or that
had a bad Frame Check Sequence (FCS), and
were less than 64 octets in length (excluding
framing bits but including FCS octets)."
::= { etherHistoryEntry 12 }
etherHistoryJabbers OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received during this
interval that were longer than 1518 octets
(excluding framing bits but including FCS octets),
and were not an integral number of octets in
length or had a bad Frame Check Sequence (FCS)."
::= { etherHistoryEntry 13 }
etherHistoryCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment during this interval."
::= { etherHistoryEntry 14 }
etherHistoryUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The best estimate of the mean physical layer
network utilization on this interface during this
interval, in hundredths of a percent."
::= { etherHistoryEntry 15 }
-- The Alarm Group
-- Implementation of the Alarm group is optional.
--
-- The Alarm Group requires the implementation of the Event
-- group.
--
-- The Alarm group periodically takes statistical samples from
-- variables in the probe and compares them to thresholds
-- that have been configured. The alarm table stores
-- configuration entries that each define a variable,
-- polling period, and threshold parameters. If a sample is
-- found to cross the threshold values, an event is
-- generated. Only variables that resolve to an ASN.1
-- primitive type of INTEGER (INTEGER, Counter,
-- Gauge, or TimeTicks) may be monitored in this way.
--
-- This function has a hysteresis mechanism to limit the
-- generation of events. This mechanism generates one event
-- as a threshold is crossed in the appropriate direction.
-- No more events are generated for that threshold until the
-- opposite threshold is crossed.
--
-- In the case of a sampling a deltaValue, a probe may
-- implement this mechanism with more precision if it takes
-- a delta sample twice per period, each time comparing the
-- sum of the latest two samples to the threshold. This
-- allows the detection of threshold crossings
-- that span the sampling boundary. Note that this does not
-- require any special configuration of the threshold value.
-- It is suggested that probes implement this more precise
-- algorithm.
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of alarm entries."
::= { alarm 1 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of parameters that set up a periodic checking
for alarm conditions."
INDEX { alarmIndex }
::= { alarmTable 1 }
AlarmEntry ::= SEQUENCE {
alarmIndex INTEGER (1..65535),
alarmInterval INTEGER,
alarmVariable OBJECT IDENTIFIER,
alarmSampleType INTEGER,
alarmValue INTEGER,
alarmStartupAlarm INTEGER,
alarmRisingThreshold INTEGER,
alarmFallingThreshold INTEGER,
alarmRisingEventIndex INTEGER (1..65535),
alarmFallingEventIndex INTEGER (1..65535),
alarmOwner OwnerString,
alarmStatus INTEGER
}
alarmIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device."
::= { alarmEntry 1 }
alarmInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be given to ensure that the variable being
monitored will not exceed 2^31 - 1 and roll
over the alarmValue object during the interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 2 }
alarmVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The object identifier of the particular variable to
be sampled. Only variables that resolve to an ASN.1
primitive type of INTEGER (INTEGER, Counter, Gauge,
or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
probe must only grant write access to this object in
those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable
name is not available in the selected MIB view, a
badValue error must be returned. If at any time
the variable name of an established alarmEntry is
no longer available in the selected MIB view, the
probe must change the status of this alarmEntry
to invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 3 }
alarmSampleType OBJECT-TYPE
SYNTAX INTEGER {
absoluteValue(1),
deltaValue(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 4 }
alarmValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the statistic during the last sampling
period. The value during the current sampling period
is not made available until the period is completed."
::= { alarmEntry 5 }
alarmStartupAlarm OBJECT-TYPE
SYNTAX INTEGER {
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a
single rising alarm will be generated. If the first
sample after this entry becomes valid is less than
or equal to the fallingThreshold and
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3), then a single falling
alarm will be generated.