From 22d24936bc71fada3eaf1169ea7bbd711d8dd087 Mon Sep 17 00:00:00 2001 From: Stefan <35419707+WordsOfMe@users.noreply.github.com> Date: Mon, 19 Aug 2024 22:36:50 +0200 Subject: [PATCH] Solax: fix grid and pv energy (#15495) Energy reported from the grid and pv meters was deviating by a factor of 100 due to a wrong scale value. --- templates/definition/meter/solax.yaml | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/templates/definition/meter/solax.yaml b/templates/definition/meter/solax.yaml index 5d5ef3d688..6c7cabcb43 100644 --- a/templates/definition/meter/solax.yaml +++ b/templates/definition/meter/solax.yaml @@ -35,7 +35,7 @@ render: | address: 74 # 0x004A consum_energy_total(meter) type: input decode: uint32s - scale: 10 + scale: 0.1 {{- end }} {{- if eq .usage "pv" }} source: calc @@ -59,7 +59,7 @@ render: | address: 148 # 0x0094 SolarEnergyTotal type: input decode: uint32s - scale: 10 + scale: 0.1 {{- end }} {{- if eq .usage "battery" }} source: modbus