Notifications
You must be signed in to change notification settings - Fork 5
/
Copy pathsequencer_top.sv
234 lines (218 loc) · 9.94 KB
/
sequencer_top.sv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
////////////////////////////////////////////////////////////////////////////////////
//
// Module: sequencer_top
//
// Description: This module performs voltage rail sequencing for power-up
// and power-down conditions. Delays and number of rails are parameterizable.
//
////////////////////////////////////////////////////////////////////////////////////
// Copyright (c) 2019 Intel Corporation
//
// Permission is hereby granted, free of charge, to any person obtaining a copy
// of this software and associated documentation files (the "Software"), to
// deal in the Software without restriction, including without limitation the
// rights to use, copy, modify, merge, publish, distribute, sublicense, and/or
// sell copies of the Software, and to permit persons to whom the Software is
// furnished to do so, subject to the following conditions:
//
// The above copyright notice and this permission notice shall be included in
// all copies or substantial portions of the Software.
//
// THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
// IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
// FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
// AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
// LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
// FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS
// IN THE SOFTWARE.
//
////////////////////////////////////////////////////////////////////////////////////
//
// Current Assumptions/Limitations:
//
////////////////////////////////////////////////////////////////////////////////////
module sequencer_top #(
parameter VRAILS = 4,
parameter PWR_GROUPS = 4,
parameter USE_OPEN_DRAIN = 1
)(
input CLOCK,
input ENABLE,
input VIN_FAULT,
input [VRAILS-1 :0] VRAIL_PWRGD,
output [PWR_GROUPS-1:0] VRAIL_ENA,
output reg [VRAILS-1:0] VMON_ENA,
output [PWR_GROUPS-1:0] VRAIL_DCHG,
output nFAULT,
input [2:0] REG_RETRIES,
input [2:0] REG_TIMEOUTDLY
);
// This file contains the timing delays for the controller. Timeunit and timeprecision appear to be needed
// by the tools to enable the time unit calculations to be performed.
timeunit 1ns;
timeprecision 1ns;
import sequencer_params_pkg::*;
reg enable_q;
wire [PWR_GROUPS-1:0] seq_enable;
wire [PWR_GROUPS-1:0] seq_keepalive;
wire [PWR_GROUPS-1:0] vrail_fault;
wire [PWR_GROUPS-1:0] fault_pwrgd;
reg [PWR_GROUPS-1:0] fault_pwrgd_q;
wire [PWR_GROUPS-1:0] next_oe;
wire [PWR_GROUPS-1:0] vrail_ena_i;
wire [PWR_GROUPS-1:0] vrail_dchg_i;
reg [PWR_GROUPS-1:0] group_pwrgd;
reg [PWR_GROUPS-1:0] group_pwrgd_hi;
reg nFault_q;
// Counter to measure delay
parameter C_CNTRSIZE = $clog2(int'(P_MAXDELAY/P_CLKPERIOD));
reg [C_CNTRSIZE-1:0] cntr_q;
wire [PWR_GROUPS:0] cntr_en;
reg [2:0] cntr_rtry_q = 3'b0;
reg cntr_rstrtdly_en;
reg seq_restart_q = 1'b1;
reg seq_restart_2q;
reg init_seqdone_q;
wire poks_low;
// Implement shared counter for sequencer state machines for delay comparison
always_ff @(posedge CLOCK) begin : P_counter
if (cntr_en == 0) cntr_q <= 0;
else cntr_q++;
end: P_counter
// Implement register to latch fault on pwrgd.
always_ff @(posedge CLOCK or negedge ENABLE) begin : P_FaultReg
if (!ENABLE) begin
fault_pwrgd_q <= {PWR_GROUPS{1'b0}};
nFault_q <= 1'b1;
end
else begin
// If we have a rising edge on our Sequencer Restart signal (for retries), clear out any current faults.
// Clear out any initial faults that might have been present prior to the initial sequence.
if (((seq_restart_q == 1'b1) && ( seq_restart_2q == 1'b0)) || (enable_q && !init_seqdone_q)) begin
fault_pwrgd_q <= {PWR_GROUPS{1'b0}};
nFault_q <= 1'b1;
end
else begin
fault_pwrgd_q <= fault_pwrgd_q | fault_pwrgd;
nFault_q <= nFault_q;
if (VIN_FAULT || (fault_pwrgd_q != 0))
nFault_q <= 1'b0;
end
end
end: P_FaultReg
// Implement the retry counter as well as the logic to safely implement the restart process.
always_ff @(posedge CLOCK) begin : P_RetryDelay
// Default assignments
cntr_rstrtdly_en <= 1'b0;
// Synchronous reset
if (!ENABLE) begin
cntr_rtry_q <= 0;
seq_restart_q <= 1'b1;
init_seqdone_q <= 1'b0;
end
// Reregister the sequencer restart signal (to generate a pulse)
seq_restart_2q <= seq_restart_q;
// Flag that indicates whether the inital power up sequence has been started
if (vrail_ena_i[0]) init_seqdone_q <= 1'b1;
// If a POK fault is detected and we're not already waiting to restart the sequencer,
// initiate the restart process by driving restart low.
if ((nFault_q == 1'b0) && (seq_restart_2q == 1'b1)) begin
seq_restart_q <= 1'b0;
end
// Start the delay counter only after all POKs are low and we are still allowed to retry
if ((cntr_en[0] == 1'b0) && (poks_low == 1'b1) && ( seq_restart_q == 1'b0) && (cntr_rtry_q < REG_RETRIES)) begin
cntr_rstrtdly_en <= 1'b1;
// Has the delay counter reached the terminal count, if so send a restart pulse
if (cntr_q >= P_RESTARTDLY[REG_TIMEOUTDLY]/P_CLKPERIOD) begin
seq_restart_q <= 1'b1;
cntr_rstrtdly_en <= 1'b0;
// The maximum number of retries for PMBus is 6. Therefore, a 7 indicates infinite retries
if (REG_RETRIES != 3'h7)
cntr_rtry_q <= cntr_rtry_q + 1'b1;
end
end
end: P_RetryDelay
// Generate the internal Power Good signal for the sequencer
generate
// AND together the Power Good signals that share the same Power Group
if (VRAILS > PWR_GROUPS) begin
always @(*) begin : P_BuildGroups
automatic reg [PWR_GROUPS-1:0] tmp_pwrgd_and = '1; // local variable (scope limited to process)
automatic reg [PWR_GROUPS-1:0] tmp_pwrgd_or = '0; // local variable (scope limited to process)
for (int i=0; i<VRAILS; i=i+1) begin
tmp_pwrgd_and[P_PWRGROUP[i]] = tmp_pwrgd_and[P_PWRGROUP[i]] & VRAIL_PWRGD[i];
tmp_pwrgd_or [P_PWRGROUP[i]] = tmp_pwrgd_or [P_PWRGROUP[i]] | VRAIL_PWRGD[i];
VMON_ENA[i] = vrail_ena_i[P_PWRGROUP[i]];
end
group_pwrgd = tmp_pwrgd_and;
group_pwrgd_hi = tmp_pwrgd_or;
end
end
// Power Groups aren't being used, so pass the Power Good signal through to the sequencers
else begin
assign group_pwrgd = VRAIL_PWRGD;
assign group_pwrgd_hi = VRAIL_PWRGD;
assign VMON_ENA = vrail_ena_i;
end
endgenerate
// Generate the enable signal to the sequencers
always_ff @(posedge CLOCK) begin : P_SeqEnable
// If we are currently not enabled, only sequence up once enable is asserted, we are allowed a restart, and all POKs are low.
// Bypass the restart logic and restart delay if this is the initial power-up sequence to eliminate any delays.
if (!enable_q) begin
if (ENABLE && poks_low && (seq_restart_q || !init_seqdone_q)) enable_q <= 1'b1;
end
// If we are currently enabled, sequence down if we receive a POK fault or ENABLE is deasserted.
else begin
if (!(nFault_q && ENABLE)) enable_q <= 1'b0;
end
end: P_SeqEnable
// Perform OR reduction on VRAIL_PWRGD. Sequencer cannot start unless all VOUT POK signals are low to ensure proper sequencing.
assign poks_low = ((VIN_FAULT == 1'b0) && (VRAIL_PWRGD == 0)) ? 1'b1 : 1'b0;
assign cntr_en[PWR_GROUPS] = cntr_rstrtdly_en;
////////////////////////////////////////////////////////////////////////////
// Asynchronous signal assigments
////////////////////////////////////////////////////////////////////////////
// Daisy chain outputs from one sequencer to the next sequencer downstream.
assign seq_enable = {PWR_GROUPS{enable_q}} & {next_oe[PWR_GROUPS-2:0],enable_q};
// This signal will be asserted if pwrgd is deasserted after it had been asserted, or if the sequencer detects a fault
assign fault_pwrgd = (next_oe & ~group_pwrgd) | vrail_fault;
// Keep upstream supplies enabled until downstream supplies have been discharged.
assign seq_keepalive = {1'b0, ~(vrail_dchg_i[PWR_GROUPS-1:1])};
// Choose between open-drain or push-pull drivers for all outputs
generate
if (USE_OPEN_DRAIN)
assign nFAULT = (nFault_q) ? 1'b1 : 1'bZ ;
else
assign nFAULT = (nFault_q);
endgenerate
// Instantiate a voltage controller per each power rail
genvar gv_i;
generate
for (gv_i=0; gv_i<PWR_GROUPS; gv_i=gv_i+1) begin: G_SEQCTRL
sequencer_ctrl #(.DLY_EN2OE(P_SEQDLY[gv_i]/P_CLKPERIOD),
.DLY_OE2PG(P_QUALTIME[gv_i]/P_CLKPERIOD),
.DLY_PNG2DCHG(P_DCHGDLY[gv_i]/P_CLKPERIOD),
.C_CNTRSIZE(C_CNTRSIZE)) U_SEQCTRL
(.CLOCK(CLOCK),
.ENABLE(seq_enable[gv_i]),
.KEEPALIVE(seq_keepalive[gv_i]),
.CNTR_EN(cntr_en[gv_i]),
.CNTR(cntr_q),
.GROUP_PWRGD_HI(group_pwrgd_hi[gv_i]),
.VRAIL_PWRGD(group_pwrgd[gv_i]),
.VRAIL_FAULT(vrail_fault[gv_i]),
.VRAIL_ENA(vrail_ena_i[gv_i]),
.VRAIL_DCHG(vrail_dchg_i[gv_i]),
.NEXT_OE(next_oe[gv_i]));
// Choose between open-drain or push-pull drivers for all outputs
if (USE_OPEN_DRAIN) begin
assign VRAIL_ENA[gv_i] = ( vrail_ena_i[gv_i]) ? 1'b1 : 1'bZ ;
assign VRAIL_DCHG[gv_i] = (~vrail_ena_i[gv_i]) ? 1'b1 : 1'bZ ;
end else begin
assign VRAIL_ENA[gv_i] = ( vrail_ena_i[gv_i]);
assign VRAIL_DCHG[gv_i] = (~vrail_ena_i[gv_i]);
end
end
endgenerate
endmodule