Add actuator_activation_duration to README.md
  • Loading branch information
DaniEll-AT authored Jan 27, 2024
2 parents 86f6ee5 + a801b62 commit 11d341d
Showing 1 changed file with 4 additions and 1 deletion.
5 changes: 4 additions & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -21,7 +21,10 @@ external_components:
components: [venetian_blinds]
```
Then you can configure the blinds. For the parameters and use refer to the [Time Based Cover](https://esphome.io/components/cover/time_based.html), with one additional parameter for `tilt_duration`.
Then you can configure the blinds. For the parameters and use refer to the [Time Based Cover](https://esphome.io/components/cover/time_based.html), with two additional parameters:
- **tilt_duration** (Required, Time): The amount of time it takes, to tilt between 0% and 100%
- **actuator_activation_duration** (Optional, Time): The amount of time it takes for the actuator/motor to start moving. Defaults to `0`.
Example: The Somfy J4 WT DataSheet states `Continuous orders of at least 200 ms must be sent to the drive to ensure proper execution.` The amount of time it takes is nondeterministic. Set `actuator_activation_duration: 200ms` for the blinds to move definitely.