Expand Up @@ -9,6 +9,43 @@ radiofrequency electromagnetic fields. FCC rule changes go into effect on May

```python
import fcc

fcc.is_compliant(150, 50, 20, 2.2, 300, 29, True, False) # SSB phone dipole 300 ft away
# (True, 'MPE')

fcc.is_compliant(0.031, 100, 100, 0, 1/12/2.54, 300, True, False) # 31 mW source nearby
# (True, 'SAR')

fcc.is_compliant(100, 50, 20, 2.2, 3, 30, True, True) # SSB phone dipole 3 ft away, controlled
# (True, 'evaluation')

fcc.is_compliant(100, 50, 20, 2.2, 1, 30, True, True) # SSB phone dipole 1 ft away, controlled
# (False, 'evaluation')
```

The arguments to the function (first execution) mean (in order): 150 W at feedpoint, 50% usage, a mode with 20% duty
(like SSB), 2.2 dBi gain (like a dipole), distance of 300 feet from antenna, 29 MHz, with ground reflection, and
uncontrolled environment. The return value tells you whether you are in compliance (True/False), **and** the means by
which compliance was determined (SAR exemption, MPE exemption, or full evaluation).

```python
fcc.rf_evaluation_report(60, 50, 20, 2.2, 6, 29, True)
# {'Power density': 0.06065253059459946,
# 'MPE controlled': 1.070154577883472,
# 'MPE uncontrolled': 0.2140309155766944,
# 'Distance controlled': 1.428408600226954,
# 'Distance uncontrolled': 3.194018729752791,
# 'Compliant controlled': True,
# 'Compliant uncontrolled': True}
```

The function arguments mean (in order): 60 W at feedpoint, 50% usage, a mode with 20% duty (like SSB), 2.2 dBi gain
(like a dipole), distance of 6 feet from antenna, 29 MHz, and with ground reflection.


## Other useful examples

```python
fcc.exempt_milliwatts_sar(1, 0.45)
# 44.372516027834514
```
Expand All @@ -21,7 +58,6 @@ is no more than" **44.4 milliwatts.** This method of exemption only
applies to UHF or higher, not VHF or HF.

```python
import fcc
fcc.exempt_watts_mpe(1, 444)
# 5.6832
```
Expand All @@ -45,20 +81,6 @@ fcc.exempt_watts_generic(0.16, 310)
This calculates a power threshold by the most favorable method
available.

```python
fcc.rf_evaluation_report(60, 50, 20, 2.2, 6, 29, True)
# {'Power density': 0.06065253059459946,
# 'MPE controlled': 1.070154577883472,
# 'MPE uncontrolled': 0.2140309155766944,
# 'Distance controlled': 1.428408600226954,
# 'Distance uncontrolled': 3.194018729752791,
# 'Compliant controlled': True,
# 'Compliant uncontrolled': True}
```

The function arguments mean (in order): 60 W at feedpoint, 50% usage, a mode with 20% duty (like SSB), 2.2 dBi gain
(like a dipole), distance of 6 feet from antenna, 29 MHz, and with ground reflection.

Mind your units! They may be different between some function arguments and
return values.

Expand All @@ -84,6 +106,10 @@ Hare, Ed (W1RFI). *RF Exposure and You.* 1st ed., American Radio Relay
League, 1998-2003. This is a perfectly lovely book.
http://www.arrl.org/files/file/Technology/RFsafetyCommittee/RF+Exposure+and+You.pdf

http://hintlink.com/power_density.htm

https://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf